INDEX.md — Updated "Your Infrastructure" Section
Replace the section starting at "## Your Infrastructure" in INDEX.md with this:
Your Infrastructure
Based on the export collected 2026-03-31, your environment includes:
Virtual Machines (QEMU/KVM)
| VM ID |
Name |
Status |
vCPU |
RAM |
Disk |
Purpose |
| 100 |
docker-hub |
Running |
4 |
10GB |
100GB |
Container registry / Docker hub mirror |
| 101 |
monitoring-docker |
Running |
2 |
8GB |
50GB |
Monitoring stack (Grafana / Prometheus / PVE Exporter) |
| 102 |
CML |
Running |
8 |
32GB |
200GB |
Cisco Modeling Labs — network simulation |
| 104 |
ubuntu-dev |
Stopped (Template) |
2 |
5GB |
32GB |
Ubuntu dev environment template |
| 105 |
pfSense-Firewall |
Stopped |
2 |
2GB |
16GB |
Firewall lab VM |
| 106 |
Ansible-Control |
Stopped |
2 |
4GB |
32GB |
IaC / Ansible control node |
| 107 |
ubuntu-docker |
Stopped (Template) |
2 |
4GB |
50GB |
Ubuntu Docker host template |
| 114 |
haos |
Stopped |
2 |
4GB |
50GB |
Home Assistant OS |
Containers (LXC)
| CT ID |
Name |
Status |
vCPU |
RAM |
IP |
Purpose |
| 109 |
caddy |
Running |
2 |
2GB |
192.168.2.129 |
Reverse proxy + SSL (replaced Nginx Proxy Manager) |
| 112 |
twingate-connector |
Running |
1 |
1GB |
DHCP |
Zero-trust remote access connector |
| 113 |
n8n |
Running |
2 |
4GB |
192.168.2.113 |
Workflow automation (PostgreSQL 16 + pgvector) |
| 117 |
test-cve-database |
Stopped |
4 |
8GB |
192.168.2.117 |
CVE database test environment |
Storage Pools
| Name |
Type |
Used% |
Total |
Purpose |
| Vault |
ZFS Pool |
~2% (110GB) |
4.36TB |
Primary VM/CT storage |
| PBS-Backups |
Proxmox Backup Server |
~29.78% |
~1TB |
Automated backups |
| iso-share |
NFS |
~1.61% |
~3TB |
ISO / installation media |
| local |
Directory |
~22.57% |
45GB |
System files, templates |
| local-lvm |
LVM-Thin |
~0.01% |
69GB |
Thin-provisioned VM disks |
Network
| Bridge |
IP |
Purpose |
| vmbr0 |
192.168.2.100/24 |
Primary LAN (eno1) |
| vmbr1 |
192.168.3.0/24 |
Internal/isolated bridge |
Proxmox host: serviceslab @ 192.168.2.100, PVE 8.4.0 (kernel 6.8.12-17-pve)
Host uptime at last export: 58 days (since ~2026-02-01)
What Changed Since Last Documentation (2025-12)
| Change |
Detail |
| Proxmox upgraded |
8.3.3 → 8.4.0 |
| NPM replaced |
Nginx Proxy Manager (CT 102) removed; Caddy (CT 109) now handles reverse proxy/SSL |
| CML expanded |
CML moved to VM 102, now running with 8 vCPU / 32GB RAM / 200GB disk |
| Removed |
CT 103 (netbox), CT 115 (TinyAuth), VM 109/110 (web servers), VM 111 (db-server), VM 120 (OpenClaw) |
| Added |
CT 117 (test-cve-database, stopped) |
| Now stopped |
VM 114 (haos), VM 106 (Ansible-Control) |